* Digester Lab
Web Gallery
Preview *
Click on the Web Gallery
Preview above to view images of
the Lansing, Michigan Digester
Lab.

* Digester Lab
11-
07 Web Gallery
Preview *
Click on the Web Gallery
Preview above to view images of
the Lansing, Michigan Digester
Lab.
Currently operate four (4) 280-L digesters.
  • Two digesters are equipped to process high solid substrate
    (top-mounted mixers)
  • Honeywell Optima Plus methane analyzer equipped with
    automated solenoid manifold that measures and logs methane
    concentration from each digester at 15 minute intervals
  • Biogas quantity measured using water displacement wet tip
    meters
  • ABB SM 2000 data logger that logs methane concentration,
    biogas production and pH for each digester
  • Each digester equipped with temperature (RTD) and pH control

Laboratory facilities include:  fume hood, Hach DR 2800
spectrophotometer, Hach DRB 200 digester, pH meter, convection
oven, muffle furnace, centrifuge and vacuum filtration apparatus
Floor view of digesters
Top view of digesters
Methane analyzer
with solenoid valve
arrangement
Wet Tip Meters
Control panel with
data logger
laboratory